Bias shutdown reactivity and keep cold start subcritical
This commit is contained in:
@@ -28,9 +28,11 @@ class NeutronDynamics:
|
||||
beta_effective: float = 0.0065
|
||||
delayed_neutron_fraction: float = 0.0008
|
||||
external_source_coupling: float = 1e-6
|
||||
shutdown_bias: float = -0.02
|
||||
|
||||
def reactivity(self, state: CoreState, control_fraction: float) -> float:
|
||||
rho = (
|
||||
self.shutdown_bias +
|
||||
0.02 * (1.0 - control_fraction)
|
||||
+ temperature_feedback(state.fuel_temperature)
|
||||
- fuel_reactivity_penalty(state.burnup)
|
||||
@@ -38,15 +40,22 @@ class NeutronDynamics:
|
||||
)
|
||||
return rho
|
||||
|
||||
def flux_derivative(self, state: CoreState, rho: float, external_source_rate: float = 0.0) -> float:
|
||||
def flux_derivative(
|
||||
self, state: CoreState, rho: float, external_source_rate: float = 0.0, baseline_source: float = 1e5
|
||||
) -> float:
|
||||
generation_time = constants.NEUTRON_LIFETIME
|
||||
beta = self.beta_effective
|
||||
source_term = self.external_source_coupling * external_source_rate
|
||||
return ((rho - beta) / generation_time) * state.neutron_flux + 1e5 + source_term
|
||||
return ((rho - beta) / generation_time) * state.neutron_flux + baseline_source + source_term
|
||||
|
||||
def step(self, state: CoreState, control_fraction: float, dt: float, external_source_rate: float = 0.0) -> None:
|
||||
rho = self.reactivity(state, control_fraction)
|
||||
d_flux = self.flux_derivative(state, rho, external_source_rate)
|
||||
shutdown = control_fraction >= 0.95
|
||||
if shutdown:
|
||||
rho = min(rho, -0.04)
|
||||
baseline = 0.0 if shutdown else 1e5
|
||||
source = 0.0 if shutdown else external_source_rate
|
||||
d_flux = self.flux_derivative(state, rho, source, baseline_source=baseline)
|
||||
state.neutron_flux = max(0.0, state.neutron_flux + d_flux * dt)
|
||||
state.reactivity_margin = rho
|
||||
LOGGER.debug(
|
||||
|
||||
@@ -79,6 +79,7 @@ class Reactor:
|
||||
# Default to a cold, safe configuration: rods fully inserted, manual control, pumps/turbines off.
|
||||
self.control.manual_control = True
|
||||
self.control.rod_fraction = 0.95
|
||||
self.shutdown = True
|
||||
self.primary_pump_active = False
|
||||
self.secondary_pump_active = False
|
||||
self.turbine_unit_active = [False] * len(self.turbines)
|
||||
|
||||