Use higher secondary pump demand to avoid meltdown
This commit is contained in:
@@ -324,7 +324,8 @@ class Reactor:
|
|||||||
pump_state.status = "STOPPING" if pump_state.flow_rate > 0.1 else "OFF"
|
pump_state.status = "STOPPING" if pump_state.flow_rate > 0.1 else "OFF"
|
||||||
if self.secondary_pump_active:
|
if self.secondary_pump_active:
|
||||||
total_flow = 0.0
|
total_flow = 0.0
|
||||||
base_flow, base_head = self.secondary_pump.performance(0.5)
|
demand = 0.75
|
||||||
|
base_flow, base_head = self.secondary_pump.performance(demand)
|
||||||
target_pressure = max(0.5, base_head * power_ratio)
|
target_pressure = max(0.5, base_head * power_ratio)
|
||||||
loop_pressure = max(0.1, saturation_pressure(state.secondary_loop.temperature_out))
|
loop_pressure = max(0.1, saturation_pressure(state.secondary_loop.temperature_out))
|
||||||
target_flow = base_flow * power_ratio
|
target_flow = base_flow * power_ratio
|
||||||
|
|||||||