Add pressurizer and coolant inventory controls
This commit is contained in:
@@ -384,9 +384,11 @@ class ReactorDashboard:
|
||||
"Flow",
|
||||
f"{state.primary_loop.mass_flow_rate:7.0f}/{self.reactor.primary_pump.nominal_flow * len(self.reactor.primary_pump_units):.0f} kg/s",
|
||||
),
|
||||
("Level", f"{state.primary_loop.level*100:6.1f}%"),
|
||||
("Inlet Temp", f"{state.primary_loop.temperature_in:7.1f} K"),
|
||||
("Outlet Temp", f"{state.primary_loop.temperature_out:7.1f} K (Target {constants.PRIMARY_OUTLET_TARGET_K:4.0f})"),
|
||||
("Pressure", f"{state.primary_loop.pressure:5.2f}/{constants.MAX_PRESSURE:4.1f} MPa"),
|
||||
("Pressurizer", f"{self.reactor.pressurizer_level*100:6.1f}% @ {constants.PRIMARY_PRESSURIZER_SETPOINT_MPA:4.1f} MPa"),
|
||||
("Relief", "OPEN" if self.reactor.primary_relief_open else "CLOSED"),
|
||||
],
|
||||
)
|
||||
@@ -401,6 +403,7 @@ class ReactorDashboard:
|
||||
"Flow",
|
||||
f"{state.secondary_loop.mass_flow_rate:7.0f}/{self.reactor.secondary_pump.nominal_flow * len(self.reactor.secondary_pump_units):.0f} kg/s",
|
||||
),
|
||||
("Level", f"{state.secondary_loop.level*100:6.1f}%"),
|
||||
("Inlet Temp", f"{state.secondary_loop.temperature_in:7.1f} K (Target {constants.PRIMARY_OUTLET_TARGET_K:4.0f})"),
|
||||
("Outlet Temp", f"{state.secondary_loop.temperature_out:7.1f} K (Target {constants.SECONDARY_OUTLET_TARGET_K:4.0f})"),
|
||||
("Pressure", f"{state.secondary_loop.pressure:5.2f}/{constants.MAX_PRESSURE:4.1f} MPa"),
|
||||
|
||||
Reference in New Issue