Add feedwater controller and turbine governor
This commit is contained in:
@@ -1,6 +1,7 @@
|
||||
# Session Context Notes
|
||||
|
||||
- Reactor model: two-loop but tuned to RBMK-like pressures (nominal ~7 MPa for both loops). Loop pressure clamps to saturation baseline when pumps are off; pumps ramp flow/pressure over spool time when stopping or starting.
|
||||
- Feedwater & level: secondary steam drum uses shrink/swell-aware level sensing to drive a feedwater valve; makeup flow scales with steam draw toward the target level instead of instant inventory clamps.
|
||||
- Turbines: produce zero output unless steam quality is present and effective steam flow is >10 kg/s. Turbine panel shows steam availability (enthalpy × quality × mass flow) and steam enthalpy instead of loop pressure; condenser pressure/temperature/fouling shown with nominal bounds.
|
||||
- Generators: two diesel units, rated 50 MW, spool time 10s. Auto mode default `False`; manual toggles b/v. Auto stops when no load. Relief valves toggles l (primary) / ; (secondary) and displayed per loop.
|
||||
- Pumps: per-unit controls g/h (primary), j/k (secondary). Flow/pressure ramp down over spool when pumps stop. Pump status thresholds use >0.1 kg/s to show STOPPING.
|
||||
@@ -16,6 +17,6 @@
|
||||
- Relief valves: l (primary) and ; (secondary) vent with mass/enthalpy loss, ramp pressure toward ~1 MPa over several seconds, cap pump targets while open; status displayed per loop.
|
||||
- Generator behavior: starting/running only produce power when load is present; auto off by default; manual toggles b/v; auto stops with no load; base aux drops to 0 when idle/cold.
|
||||
- Pressure tying: loop pressure floors to saturation(temp) when pumps off; pump targets aim for ~7 MPa nominal RBMK-like setpoints.
|
||||
- Turbines: require meaningful steam flow/quality; otherwise zero output. Steam supply pressure in turbine panel reads 0 when no steam.
|
||||
- Turbines/governor: require meaningful steam flow/quality; otherwise zero output. Steam supply pressure in turbine panel reads 0 when no steam. Throttle now biases toward load demand with a governor term, and overspeed/overload >105% rated electrical trips a unit and spools it down.
|
||||
- Rod control now supports three banks with weighted worth; xenon/iodine tracked with decay and burn-out; new UA·ΔT_lm steam-generator model and pump head/flow curves.
|
||||
- Dashboard shows heat-exchanger ΔT/efficiency and protections; pumps and HX changes documented in FEATURES.md / TODO.md.
|
||||
|
||||