Stop pressurizer pumping a cold loop
This commit is contained in:
@@ -309,8 +309,7 @@ class Reactor:
|
||||
state.primary_loop.mass_flow_rate = self._ramp_value(
|
||||
state.primary_loop.mass_flow_rate, 0.0, dt, self.primary_pump.spool_time
|
||||
)
|
||||
pressurizer_floor = constants.PRIMARY_PRESSURIZER_SETPOINT_MPA - 0.5 if self.pressurizer_level > 0.05 else 0.5
|
||||
target_pressure = max(pressurizer_floor, saturation_pressure(state.primary_loop.temperature_out))
|
||||
target_pressure = max(0.5, saturation_pressure(state.primary_loop.temperature_out))
|
||||
state.primary_loop.pressure = self._ramp_value(
|
||||
state.primary_loop.pressure, target_pressure, dt, self.primary_pump.spool_time
|
||||
)
|
||||
@@ -551,6 +550,8 @@ class Reactor:
|
||||
return max(0.0, min(1.0, available / constants.NPSH_REQUIRED_MPA))
|
||||
|
||||
def _apply_pressurizer(self, primary: CoolantLoopState, dt: float) -> None:
|
||||
if self.shutdown and primary.mass_flow_rate <= 100.0:
|
||||
return
|
||||
target = constants.PRIMARY_PRESSURIZER_SETPOINT_MPA
|
||||
band = constants.PRIMARY_PRESSURIZER_DEADBAND_MPA
|
||||
heat_rate = constants.PRIMARY_PRESSURIZER_HEAT_RATE_MPA_PER_S
|
||||
|
||||
Reference in New Issue