Clamp turbine spin-down status to OFF when near zero
This commit is contained in:
@@ -371,7 +371,7 @@ class Reactor:
|
|||||||
turbine_state.status = "RUN"
|
turbine_state.status = "RUN"
|
||||||
else:
|
else:
|
||||||
self._spin_down_turbine(turbine_state, dt, turbine.spool_time)
|
self._spin_down_turbine(turbine_state, dt, turbine.spool_time)
|
||||||
turbine_state.status = "STOPPING" if turbine_state.electrical_output_mw > 0 else "OFF"
|
turbine_state.status = "STOPPING" if turbine_state.electrical_output_mw > 0.1 else "OFF"
|
||||||
self._dispatch_consumer_load(state, active_indices)
|
self._dispatch_consumer_load(state, active_indices)
|
||||||
|
|
||||||
def _reset_turbine_state(self, turbine_state: TurbineState) -> None:
|
def _reset_turbine_state(self, turbine_state: TurbineState) -> None:
|
||||||
@@ -397,6 +397,8 @@ class Reactor:
|
|||||||
turbine_state.load_supplied_mw = self._ramp_value(
|
turbine_state.load_supplied_mw = self._ramp_value(
|
||||||
turbine_state.load_supplied_mw, 0.0, dt, time_constant
|
turbine_state.load_supplied_mw, 0.0, dt, time_constant
|
||||||
)
|
)
|
||||||
|
if turbine_state.electrical_output_mw < 0.1:
|
||||||
|
turbine_state.electrical_output_mw = 0.0
|
||||||
|
|
||||||
def _dispatch_consumer_load(self, state: PlantState, active_indices: list[int]) -> None:
|
def _dispatch_consumer_load(self, state: PlantState, active_indices: list[int]) -> None:
|
||||||
total_electrical = sum(state.turbines[idx].electrical_output_mw for idx in active_indices)
|
total_electrical = sum(state.turbines[idx].electrical_output_mw for idx in active_indices)
|
||||||
|
|||||||
Reference in New Issue
Block a user